MICROSENS User Manual Device Server RS-232/422/485 Port to 1x or 2x 10/100TX
and Device Server RS-232/422/485 Port to 1x 100FX
Hardware Description
This section mainly describes the hardware of Device Server.
Physical Dimension
The physical dimensions of Device Server are 72mm(W) x 100mm(D) x
32mm(H)
Top & Bottom
The top & bottom of the Device Server picture are shown as below.
PWR1: Insert the positive and negative wires into the V+ and V- holes to the
PWR1 on the terminal block connector.
PWR2: Insert the DC power supply adapter to PWR2 DC jack with 12V or 24V. In
the beginning the power LED is red, and after the system is successful initialized,
it turns green. In addition, if PWR1 and PWR2 are connected at the same while,
the device server will work with the higher connected voltage.
Ethernet (1 RS-232/422/485 port to 1 10/100TX Device Server): 10/100Mbps
redundant Ethernet RJ-45 ports both support Auto MDI/MDIX.
Top side of 1 RS-232/422/485 port to 1 10/100TX Device Server
5