MICROSENS User Manual Device Server RS-232/422/485 Port to 1x or 2x 10/100TX
and Device Server RS-232/422/485 Port to 1x 100FX
DIP Switch
DIP 1 DIP 2 120 Termination Configuration
ON ON
120 Terminator for Long Distance 4-wire RS-485/RS-422
ON OFF
OFF ON
120 Terminator for Long Distance 2-wire RS-485
OFF OFF No terminator for RS-232/485 (short distance)
LED Indicators
The LED Indicators gives real-time information of systematic operation status. The
following table provides descriptions of LED status and their meaning.
LED Status
Meaning
Red On Power is on and booting up.
Red
Blinking
Indicates an IP conflict, or DHCP or
BOOTP server does not respond
properly.
Green On Power is on and works functionally
PWR1
Green
Blinking
Located by Administrator’s Location
function.