4 Port Industrial Device Server Manual page 17/36
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Delimiter:
You can define max. 4 delimiters (00~FF, Hex) for each way. The data will be
hold until the delimiters are received or the option “Flush Ethernet to Serial
data buffer” times out. 0 means disable. Factory default is 0.
Flush Data Buffer After:
The received data will be queuing in the buffer until all the delimiters are
matched. When the buffer is full (4K Bytes) or after "flushE2S data buffer"
timeout the data will also be sent. You can set the time from 0 to 65535
seconds.
Force TX interval time is to specify the timeout when no data has been
transmitted. When the timeout is reached or TX buffer is full (4K Bytes), the
queued data will be sent. 0 means disable. Factory default value is 0.
Service Mode – Virtual COM Mode
In Virtual COM Mode, The driver establishes a transparent connection between host
and serial device by mapping the Port of the serial server serial port to local COM
port on the host computer. Virtual COM Mode also supports up to 5 simultaneous
connections, so that multiple hosts can send or receive data by the same serial
device at the same time.
Kommentare zu diesen Handbüchern