4 Port Industrial Device Server Manual page 33/36
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
The following table describes the labels in this screen.
Hardware Reset
(Cold Start)
This refers to starting the system from power off (contrast this with
warm start). When performing a cold start, Device Server will
automatically issue an Auto warning message by sending E-mail, log
information or an SNMP trap after booting.
Software Reset
(Warm Start)
This refers to restart the computer without turning the power off.
When performing a warm start, Device Server will automatically send
an E-mail, log information or SNMP trap after reboot.
When an unauthorized access from the Console or Web interface, a
notification will be sent.
When IP address of device changed, a notification will be sent.
When password of device changed, a notification will be sent.
When the host accesses the device with blocked IP addresses, a
notification will be sent.
When status of power changed, a notification will be sent.
Redundant
Ethernet Change
When status of Ethernet port changed, a notification will be sent.
When DCD (Data Carrier Detect) signal changes, it indicates that the
modem connection status has been changed. A Notification will be
sent.
When DSR (Data Set Ready) signal changes, it indicates that the data
communication equipment is powered off. A Notification will be sent.
When RI (Ring Indicator) signal changes, it indicates an incoming call.
Notification will be sent.
When CTS (Clear To Send) signal changes, it indicates that the
transmission between computer and DCE can proceed. A notification
will be sent.
In TCP Server Mode, when the device accepts an incoming TCP
connection, this event will be trigger. In TCP Client Mode, when the
device has connected to the remote host, this event will be trigger. In
Virtual COM Mode, Virtual COM is ready to use. A notification will be
sent.
In TCP Server/Client Mode, when the device lost the TCP link, this
event will be trigger. In Virtual COM Mode, When Virtual COM is not
available, this event will be trigger. A notification will be sent.
When Power 1 Fault, a notification will be sent and the Fault LED will
be lighted.
When Power 2 Fault, a notification will be sent and Fault LED will be
lighted.
When Eth1 link down, a notification will be sent and Fault LED will be
lighted.
When Eth2 link down, a notification will be sent and Fault LED will be
lighted.