Preventive Maintenance
Dust Filter replacement Procedure
The dust filter should be visually examined on a six month basis.
Procedure
Using a cross head screwdriver loosen the two holding screws on the
frontplate, located at both sides of the FAN front panel (see picture below)
Replace the dust filter on the FAN front panel
Put back the FAN front panel
Using a cross head screwdriver tighten the two holding screws on the
frontplate, located at both sides of the FAN front panel
Check that the dust filter presence LED is green on the FAN front panel
End procedure
Figure 11: FAN front panel.
Corrective Maintenance
Management Board MGNT
MGNT Replacement Procedure
Use the following procedure to replace a MGNT management board:
Procedure
Perform a full inventory on the MGNT using the objects:
mgnt2RinvHwPlatform
mgnt2RinvSoftwarePackage
mgnt2RinvGateware
mgnt2RinvAgent
Location: ...\microsens\mgnt2\mgnt2RemoteInventory