19'' 6U Chassis page 46/71
Resets
The following describes the various methods of resetting the MGNT board.
Under no circumstances should a Reset be attempted during the Installation Phase of
the SNMP Agent Update procedure. Consult the object:
mgnt2PackageExtractionInProgress. Ensure it is set to “off” before continuing.
Warm reset
This reset has no effect on the traffic and takes 35 seconds to complete.
Procedure
Start the reset:
Set to “on “the object: mgnt2CtrlChassisWarmReset
Location:
…\microsens\mgnt2\mgnt2Hardware\mgnt2controls\mgnt2Ctrlsynth5\
Visual indication:
The colour sequence of the SW LED on the front panel of the MGNT during a
warm reset is:
Green > Red (few seconds) > Orange (less than 1 second) > Green
Under normal conditions all LEDs return to green when the reset is complete.
Refer to LED status table in Appendixes. The duration of a MGNT warm reset is
approximately 35 seconds, during which time the management function is
unavailable.
End procedure
Hardware reset
A hardware reset may be also performed on the MGNT. This reset has no effect on the
traffic and takes 35 seconds to complete.
Procedure
Use a needle-like tool (i.e. paper clip) to reach the MGNT reset button and
press it during 1 second to perform a hardware reset of the MGNT.