19'' 6U Chassis page 51/71
Upload a configuration
A user may upload the configuration of a MSxxxxxxx module to a PC via the MGNT
management board. The user gets the MSxxxxxxx configuration in an XML-like file. To
achieve this, you will need:
• An SNMP V2C browser (for reading and updating values in the MIB)
• A TFTP client
The configuration uploading procedure is carried out in three phases:
1. Create a backup file of MSxxxxxxx configuration in the FLASH memory (conf
partition) of the MGNT management board.
2. Transferring the backup file from the MGNT FLASH memory to the MGNT
RAM memory
3. Get the backup file in the MGNT RAM memory via a TFTP command.
Described in more detail as follows:
Procedure
1. Create a backup file
The object of this phase is to read the configuration of a dedicated MSxxxxxxx module
and store this configuration in a backup file.
• Use your SNMP browser to check the backup file presence in the FLASH
memory of the MGNT management board using the table:
• mgnt2CnfManageConfigFilesTable
Location: …\microsens\mgnt2\mgnt2ConfigManagement
There is one dedicated backup file for each MS430502M chassis Slot. At this stage
in the procedure, there should be no file in the FLASH memory.
• Create a backup file of configuration by setting:
mgnt2CnfBackupConfig
Location:…
\microsens\mgnt2\mgnt2ConfigManagement\mgnt2CnfManageConfigFilesTable
Linked to the dedicated MSxxxxxxx module. The MSxxxxxxx module is referenced
by the slot number where it is plugged in.
At this moment, a backup file is created in the FLASH memory of the MGNT
management board.
The back up file name is respecting the following format:
bkpConf + ‘slot number’
For instance, the backup file of the MS43062XM plugged in slot 5 will have the
following name:
bkpConf05