19'' 6U Chassis page 47/71
Figure 14: MGNT Management board reset button.
Visual indications:
The colour sequence of the front panel LEDs are:
HW LED: Red (while the reset button is pressed) > Green
SW LED: Off (few seconds) > Orange (less than 1 second) > Green
Under normal conditions all LEDs return to green when the reset is complete.
The duration of a MGNT warm reset is approximately 35 seconds, during which
time the management function is unavailable.
End procedure
MGNT Unplug/Plug
Another method of reset is to unplug/uinplug the MGNT This reset has no effect on the
traffic and takes 35 seconds to complete.
Procedure
Before the extraction of the MGNT, it is mandatory to power it down.
• MGNT Software stop:
Before unplug the MGNT, it is mandatory to stop the MGNT software. There are several
ways to stop the MGNT software:
• Using the test button on the front panel
• Push up the test button for 10 seconds
• Using a SNMP object