19'' 6U Chassis page 17/71
ms43062XMRinvSfpTable
Location: ...\microsens\modulems43062XM\ms43062XMri\
Use you SNMP browser to check if there is a backup file linked to the MS
module using the object:
mgnt2CnfManageConfigFilesTable
Location: …\microsens\mgnt2\mgnt2ConfigManagement
If necessary (i.e. if the backup file is absent), create a backup file setting “on”
the object:
mgnt2CnfBackupConfig associated with the slot number where the
MS module is being replaced.
Location:
\microsens\mgnt2\mgnt2ConfigManagement\mgnt2CnfManageConfigFilesTable
Verify that the wrist strap you are wearing is properly grounded or that
other antistatic measures are in place
Take the necessary steps to minimise the impact on your network, traffic by-
pass re-route etc.
Disconnect any cables connected to the Line and the client ports on the
module
Using a flat head screwdriver loosen the two holding screws on the
frontplate, located at the top right-hand and bottom left-hand corners
Pull the module out of the chassis, unplugging the backplane connectors,
and set aside
Line up the replacement module with the rails and gently slide in, plugging
in the backplane connectors
Do not force the module into place as this could lead to damage to the connectors on
the module and/or the connectors on the back panel of the chassis.
Re-connect cables to the Line and the client ports on the module
Observe behaviour of LEDs
Check the module has been correctly detected by the MGNT board using the
object:
mgnt2GigmBoardTable
Location:…
\microsens\mgnt2\mgnt2SNMPAgentData\mgnt2ModulesManagement\
If a backup file is dedicated to the slot number in the MGNT management
board, the configuration of the MS module is automatically updated,
identical to the one saved previously
It is recommended to perform a cold reset of the MS module
Perform a full inventory on the module
Re-integrate into your network
End procedure