Associated with the package to be erased.
If the package that you intend to erase from the FLASH is in use, i.e.:
mgnt2ExtractedPack = "two", this operation will have no effect. Erasure of a
package in use in prohibited.
End procedure
Generic slot MS Module Code Update
A user may update the MS Module Code, Software or Gateware, remotely. To achieve
this you will need:
An SNMP V2C browser. (For reading and updating values in the MIB)
A tftp client.
The Module Code update procedure is carried out in three phases:
1. Remote loading of the code via tftp into the MS430502M chassis
2. Transferring to the generic slot MS
3. Activation and Verification of the new code
Described in more detail as follows:
The following procedure is common to all modules type (MS43062XM, MS430601M,
etc…), but some OIDs are module dependant. So in the complete procedure, all the
module OID are referenced using the following notation:
msXXXXXXXDwlSwBank1Notempty
This OID gives the status of the SW bank 1 for the MS43062XM when XXXXXXX is equal
to 43062Xm, for the MS430601M when XXXXXXX is equal to 430601m, etc…
Procedure
1. Remote Loading Phase
The object of this phase is to load the code into the RAM of the MS430502M chassis
MGNT. There are no service implications during this phase.
Use your SNMP browser to perform a table update and check the status of
the RAM using the table:
mgnt2LoadMSTable
Location: ...\microsens\mgnt2\mgnt2SoftwareManagement
There is space for one file in the RAM, at this stage in the procedure there
should be none.
Open a Command Line Interface window from your operating system and go
to the directory where you placed the new code
In the example the file extension is given as .ext. In reality the file extension will
depend on the type of code you are dealing with:
*.srec => Software
*.hexout => Gateware
Enter the line (Windows XP):
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com